Ë÷¿ËÂüUPSµçÔ´£¨Öйú£©ÓÐÏÞ¹«Ë¾ ¹«Ë¾µØÖ·£ºÉϺ£ÊÐÑÓ°²Î÷·1118ºÅÁúÖ®ÃδóÏà ÁªÏµµç»°£º13082750998 ÊÖ»úºÅÂ룺13082750998 ÁªÏµÈË£ºÍõ¾Àí E-MAIL£º2743798812@qq.com
|
|
|
|
|
Ë÷¿ËÂüDELPHYS GP - Green Power 2.0 range |
ÄúÏÖÔÚµÄλÖãºÍøÕ¾Ê×Ò³ >> ²úÆ·ÖÐÐÄ >> Ë÷¿ËÂüÈýÏà/ÈýÏàUPS |
|
|
Ë÷¿ËÂüDELPHYS GP - Green Power 2.0 range |
|
|
|
½â¾ö·½°¸ÊÊÓÃÓÚ£º
• Êý¾ÝÖÐÐÄ
• µçÐÅ
• ·þÎñ²¿ÃÅ
• ITÍøÂç/»ù´¡ÉèÊ©
Óŵã
½ÚÄÜ+ ¶î¶¨¹¦ÂÊÂúÔØ = ×ÜÌåÓµÓгɱ¾£¨TCO£©
µçÄܽÚÔ¼£º¸ßЧ¡¢ÃæÃæ¾ãµ½
• Êг¡ÉÏΨһʹÓÃVFI-ÔÚÏß˫ת»»Ä£Ê½Ìṩ×î¸ßÄÜЧµÄUPS£¬VFI-ÔÚÏß˫ת»»Ä£Ê½ÊÇΨһµÄÔÚËùÓÐÊеçÖÊÁ¿ÎÊÌâϱ£ÕÏ×ܸºÔصIJ»¼ä¶ÏµçÔ´£¨UPS£©¹¤×÷ģʽ¡£
• ³¬¸ßÄÜЧÊä³öÊǶÀÁ¢µÄ¹ú¼ÊÈÏÖ¤»ú¹¹ÔÚ²»Í¬Êµ¼Ê²Ù×÷Ìõ¼þϲâÊÔ²»ÈÏÖ¤µÄ¡£
• ´´Ð¼¼Êõ£¨ÈýÖÖ¼¼Êõ£©ÌṩVFIģʽ³¬¸ßÄÜЧ£¬²¢ÒѾ¿ª·¢³ÉËùÓÐGreen Power²»¼ä¶ÏµçÔ´£¨UPS£©²úÆ·¡£
¶î¶¨¹¦ÂÊÂúÔØ£º kW=kVA
• ÔÚµäÐÍÊý¾ÝÖÐÐÄ»·¾³ÏÂΪ×îÐÂÒ»´ú·þÎñÆ÷¹©µç²»´æÔÚ¹¦ÂʽµµÍ
• È«¹¦Âʲ»¼ä¶ÏµçÔ´£¨UPS£©Éè¼Æ´ï 35 ¡ãC£¬Ïà½ÏÓÚÊä³ö¹¦ÂÊÒòÊýΪ0.8µÄUPSÌá¸ßÁË25%µÄÓй¦Êä³ö£¬Ïà½ÏÓÚÊä³ö¹¦ÂÊΪ0.9µÄUPSÌá¸ßÁË11%µÄÓй¦Êä³ö
• ÊÊÓÃÓÚÖ÷Á÷¹¦ÂÊÒòÊý0.9¶øÎÞÐëµ÷½µ
ÏÔÖø½ÚÔ¼³É±¾ (×ÜÌåÓµÓгɱ¾TCO)
• ½ÚÄÜ×î´ó»¯¹é¹¦ÓÚ96%µÄÊä³öÄÜЧ£ºÔÚµçÄÜÕ˵¥ÉϽÚÔ¼50%µçÄÜËðʧ£¬Ïà½ÏÓÚ´«Í³UPS
• UPSͨ¹ý½ÚÄÜ¡°Îª×Ô¼ºÂòµ¥¡±
• ½ÚÄÜģʽÓÃÓÚ²¢ÁªÄ£Ê½ÏÂÌáÉýÈ«¾ÖÄÜЧ
kW=kVAÒâÍâ×Å×î´ó¹¦ÂÊ¿ÉÓÃÐÔ£¬Ïà½ÏÓÚͬ³ß´çµÄUPS£¬Òò¶ø¸üÉٵĀ/kW
• ͨ¹ýÆä"Çå½àÕûÁ÷Æ÷"£¬Green Power UPSÏÔÖøÓÅ»¯ÆäÉÏÓλù´¡ÉèÊ©ÎÞÐëµ÷½µ¹©µçϵͳ£¨Èç·¢µç»ú×é¡¢¿ª¹Ø¡¢µçÀºͱ£»¤×°Öã©
• ¸ßÄÜЧʹµÃͬµÈ±¸ÓÃʱ¼äËùÐèµÄµç³Ø×éÊýÁ¿×îС»¯
• ÒòÆä¹ã·ºµÄÖ±Á÷µç·¶Î§¿ÉÒÔÓÅ»¯µç³ØÅäÖÃ
• ÑÓ³¤µç³ØÊÙÃü²¢ÔöÇ¿µç³ØÐÔÄÜ
- µç³ØʹÓÃÊÙÃü³¤
- ÊäÈëµçѹ·¶Î§·Ç³£´ó (-40% / +20%)ºÍÊäÈëƵÂÊ·¶Î§·Ç³£´ó(45µ½65 Hz) ÎÞÐëʹÓõç³Ø
- ר¼Òµç³Øϵͳ£¨EBS£©³äµç¹ÜÀíÑÓ³¤µç³ØʹÓÃÊÙÃü |
|
|
|
¼¼Êõ²ÎÊý
Sn (kVA) |
160 |
200 |
250 |
320 |
400 |
500 |
600 |
800 |
Pn [kW] |
160 |
200 |
250 |
320 |
400 |
500 |
600 |
800 |
ÊäÈë/Êä³ö |
3/3 |
±äÁ¿ÅäÖà |
´ï4MW |
ÊäÈë |
¶î¶¨µçѹ |
400V 3ph |
µçѹÈÝÐíÆ«²î |
200 V µ½480 V (1) |
¶î¶¨ÆµÂÊ |
50 / 60 Hz |
ƵÂÊÈÝÐíÆ«²î |
± 10 Hz |
¹¦ÂÊÒòÊý/µçÁ÷×Üг²¨»û±äÂÊ£¨THDI£© |
> 0.99 / < 2.5%(2) |
Êä³ö |
¶î¶¨µçѹ |
3ph + N 400 V |
¾²Ì¬¸ºÔصçѹÈÝÐíÆ«²î |
¾²Ì¬¸ºÔØ ±1% ¶¯Ì¬¸ºÔØ·ûºÏ VFI-SS-111 |
¶î¶¨ÆµÂÊ |
50 / 60 Hz |
ƵÂÊÈÝÐíÆ«²î |
± 2% (¿ÉÅäÖÃÒÔ±ã¼æÈÝ·¢µç»ú×é) |
×ÜÊä³öµçѹ»û±ä - ÏßÐÔ¸ºÔØ |
µçÁ÷Êä³ö×Üг²¨»û±äÂÊThdU < 1.5% |
×ÜÊä³öµçѹ»û±ä - ·ÇÏßÐÔ¸ºÔØ
(lEC 62043-3) |
µçÁ÷Êä³ö×Üг²¨»û±äÂÊ ThdU< 3% |
¶Ì·µçÁ÷ |
´ï3.4 x In |
ÅÔ· |
¶î¶¨µçѹ |
¶î¶¨Êä³öµçѹ |
µçѹÈÝÐíÆ«²î |
± 15% (´Ó10%µ½20%¿ÉÅäÖÃ) |
¶î¶¨ÆµÂÊ |
50/60 Hz |
ƵÂÊÈÝÐíÆ«²î |
± 2% (¿ÉÅäÖÃÒÔ±ã¼æÈÝ·¢µç»ú×é) |
ÄÜЧ |
ÔÚÏßģʽ @ 40 %¸ºÔØ |
´ï96% |
ÔÚÏßģʽ@ 75 %¸ºÔØ |
´ï96% |
ÔÚÏßģʽ @ 100 %¸ºÔØ |
´ï96% |
¿ìËÙ½ÚÄÜģʽ |
´ï99% |
»·¾³ |
ÔËÐл·¾³ÎÂ¶È |
´Ó10 °C µ½ +40 °C (1) (´Ó15 °Cµ½25 °CÒÔ±ã×î¼Ñµç³ØʹÓÃÊÙÃü) |
Ïà¶Ôʪ¶È |
0 % - 95% ²»Äý½á |
×î¸ßº£°Î |
1000 m ²»½µ¶î (×î¸ß3000 m) |
1Ã×´¦ÔëÉùµÈ¼¶(ISO 3746) |
<65 dBA |
<67 dBA |
<70 dBA |
<68 dBA |
<70 dBA |
<74 dBA |
UPS¹ñ |
³ß´ç(W x D x H) |
700 x 800 x 1930 mm |
1000 x 950 x 1930 mm |
1400 x 800 x 1930 mm |
1600 x 950 x 1930 mm |
2800 x 950 x 2055 mm |
3700 x 950 x 2060 mm |
ÖØÁ¿ |
470 kg |
490 kg |
850 kg |
980 kg |
1000 kg |
1500 kg |
2300 kg |
3400 kg |
·À»¤µÈ¼¶ |
IP 20 (ÆäËûIPµÈ¼¶¿ÉÑ¡) |
ÑÕÉ« |
¹ñ£ºRAL 7012£¬ÃÅ£ºÒø»ÒÉ« |
±ê×¼ |
°²È« |
EC/EN 62040-1, EN 60950-1, AS 62040.1.1, AS 62040.1.2 |
µç´Å¼æÈÝÐÔ£¨EMC£© |
IEC/EN 62040-2, AS 62040.2 |
ÐÔÄÜ |
VFI-SS-111 - IEC/EN 62040-3, AS 62040.3 |
²úÆ·ÈÏÖ¤ |
CE, RCM (E2376) |
|
(1) ÊÊÓÃÌõ¼þ
|
|